Sample information |
|
| Picture |
|
|---|---|
| Location | Approximate location: 38.94, -77.09 |
| Collection date | 09/10/2026 |
| Captive / Cultivated? | Wild-caught |
| Group | Edmund Burke School |
| Observations | Ting, smaller than an ant, no visual antennae, two large body parts, many small spiders on the same web. Caught in 80 F on a summer day. Caught in an urban environment. Caught on the sidewalk on a web. |
| Putative identification | Arthropoda Arachnida Araneae Linyphiidae Idionella Idionella rugosa |
Methods |
|
| Extraction kit | DNeasy (Qiagen) |
| DNA extraction location | Whole arthropod |
| Single or Duplex PCR | Single Reaction |
| Gel electrophoresis system | MiniOne |
| Buffer | 1X TBE |
| DNA stain | GelGreen |
| Gel images |
|
| Protocol notes | DNA extraction – A pipette tip fell into the E1 tube – Less liquid appeared during the DNA purification PCR lab – Accidentally added water to E1 tube Gel electrophoresis (Arthropod CO1) – Lane 1-9: DNA ladder, E1, E2, E3, E4, E5, W+, W-, H2O – W+ displayed both an arthropod band, meaning that our PCR lab successfully amplified arthropod DNA – W- also displayed an arthropod band, meaning the arthropod DNA was successfully amplified in our PCR lab – H2O didn’t display an arthropod band, meaning there was no contamination from arthropod DNA – No mistakes were made Gel Electrophoresis (Wolbachia) – Lane 1-9: DNA ladder, E1, E2, E3, E4, E5, W+, W-, H2O – W+ displayed a Wolbachia band, meaning that our PCR lab successfully amplified Wolbachia DNA – W- didn’t display a Wolbachia band, meaning there was zero contamination from the Wolbachia DNA – H2O didn’t display neither aWolbachia band, meaning there was no contamination from Wolbachia DNA – No mistakes were made |
Results |
|
| Wolbachia presence | No |
| Confidence level | High |
| Explanation of confidence level | Our confidence level is high – No visible errors in results (arthropod band was present in CO1 gel), or in previous labs. – W+ displayed both an arthropod and Wolbachia band, meaning that our PCR lab successfully amplified Wolbachia and arthropod DNA – W- displayed only an arthropod band, meaning there was zero contamination from the Wolbachia DNA and the arthropod DNA was successfully amplified – H2O displayed neither an arthropod or Wolbachia band, meaning there was no contamination from either Wolbachia or arthropod DNA
|
| Wolbachia 16S sequence | |
| Arthropod COI sequence | Download FASTA
Download AB1
|
| Summary | The Idionella rugosa was found to be negative for Wolbachia. |