Sample information |
|
| Picture |
|
|---|---|
| Location | Approximate location: 39.00, -77.00 |
| Collection date | 09/06/2026 |
| Captive / Cultivated? | Wild-caught |
| Group | Edmund Burke School |
| Observations | Mouth shape: external mandible for chewing For leg shape and size: Modified for seizing pray Hind leg shape and size: Not modified Body regions Two Number of legs: Eight Body shape: Not compressed Eyes: separated Color: Dark brown Found in terrestrial environment, gravel parking lot, during summer, 77 Degrees F |
| Putative identification | Arthropoda Arachnida Araneae |
Methods |
|
| Extraction kit | DNeasy (Qiagen) |
| DNA extraction location | Abdomen |
| Single or Duplex PCR | Single Reaction |
| Gel electrophoresis system | MiniOne |
| Buffer | TBE |
| DNA stain | GelGreen |
| Gel images |
|
| Protocol notes |
When we detached the abdomen from the body to extract the DNA we were unable to extract enough organs to get DNA
We re-ran the PCR to see if it was the DNA extraction failed or if the PCR failed, it was indeed the DNA extraction
Lane 1 had the ladder, then the following lanes had (in this order) D1,D2,D3,D4,D5,W+,W-,H20 there was no band present for D3 meaning the there was no DNA or the DNA was not amplified enough, the rerun confirmed that there was not DNA to be amplified Controls worked, they served to confirm that our Eelectrophoresis machines were working and our W+ and W- helped confirm that we correctly amplified the Arthopod DNA on either run and H20 confirmed no contamination in either run
Lane 1 had the ladder, then the following lanes had (in this order) D1,D2,D3,D4,D5,W+,W-,H20 No bands were present for any other then the W+ controls meaning that none were infected Controls worked, they served to confirm that our Eelectrophoresis machines were working and the W+ helped confirm that we amplified the W+ DNA correctly on both attempts and the W- and H20 confirmed we did not have any contamination in either attempt |
Results |
|
| Wolbachia presence | Unknown |
| Confidence level | High |
| Explanation of confidence level | Made a mistake somewhere in the DNA extraction process, likely not enough DNA was extracted, no results show. The W+ and W- controls helped us confirm this since in both tests they confirmed that we had run it correctly and it wasn’t an issue with the PCR or Electrophoresis labs since the controls all worked as intended, leading to our high confidence in our unknown results. The W+ band showed up for the Arthopod CO1 gel so we know that the DNA was correctly amplified and the PCR was not the issue |
| Wolbachia 16S sequence | |
| Arthropod COI sequence |
|
| Summary | |



Curinus Coeruleus
Aphid
(no title)
Rusty Millipede
A-2 Arachnida