D3, Aranae

Sample information

Picture
Entry by: Luca R
Location
Approximate location: 39.00, -77.00
Collection date 09/06/2026
Captive / Cultivated? Wild-caught
Group Edmund Burke School
Observations

Mouth shape: external mandible for chewing

For leg shape and size: Modified for seizing pray

Hind leg shape and size: Not modified

Body regions Two

Number of legs: Eight

Body shape: Not compressed

Eyes: separated

Color: Dark brown

Found in terrestrial environment, gravel parking lot, during summer, 77 Degrees F

Putative identification Arthropoda Arachnida Araneae

Methods

Extraction kit DNeasy (Qiagen)
DNA extraction location Abdomen
Single or Duplex PCR Single Reaction
Gel electrophoresis system MiniOne
Buffer TBE
DNA stain GelGreen
Gel images
Protocol notes
  • DNA Extraction

When we detached the abdomen from the body to extract the DNA we were unable to extract enough organs to get DNA

 

  • PCR

We re-ran the PCR to see if it was the DNA extraction failed or if the PCR failed, it was indeed the DNA extraction

  • Gel electrophoresis, Arthropod CO1

Lane 1 had the ladder, then the following lanes had (in this order) D1,D2,D3,D4,D5,W+,W-,H20

there was no band present for D3 meaning the there was no DNA or the DNA was not amplified enough, the rerun confirmed that there was not DNA to be amplified

Controls worked, they served to confirm that our Eelectrophoresis machines were working and our W+ and W- helped confirm that we correctly amplified the Arthopod DNA on either run and H20 confirmed no contamination in either run

  • “Gel electrophoresis, Wolbachia”:

Lane 1 had the ladder, then the following lanes had (in this order) D1,D2,D3,D4,D5,W+,W-,H20

No bands were present for any other then the W+ controls meaning that none were infected

Controls worked, they served to confirm that our Eelectrophoresis machines were working and the W+ helped confirm that we amplified the W+ DNA correctly on both attempts and the W- and H20 confirmed we did not have any contamination in either attempt

Results

Wolbachia presence Unknown
Confidence level High
Explanation of confidence level

Made a mistake somewhere in the DNA extraction process, likely not enough DNA was extracted, no results show. The W+ and W- controls helped us confirm this since in both tests they confirmed that we had run it correctly and it wasn’t an issue with the PCR or Electrophoresis labs since the controls all worked as intended, leading to our high confidence in our unknown results. The W+ band showed up for the Arthopod CO1 gel so we know that the DNA was correctly amplified and the PCR was not the issue

Wolbachia 16S sequence
Arthropod COI sequence
Summary
Report Inappropriate Post